新聞資訊

NEWS INFORMATION

Building Safety Product Integrator

Automatic door installation requirements

Automatic door installation requirements

    The installation requirements of automatic doors are as follows:

    1. Ground requirements: before installation, the construction site should be checked to see whether the site condition meets the construction requirements. For example: the power supply must be sent in place, the ground is flat, and all the construction conditions can be started. To ensure the installation precision of automatic door and use function, before the automatic door installation requirement will be treated as their ground to a smooth horizontal plane, the door on both sides of the ground is not flatness less than plus or minus 3 mm, automatically using expansion bolt, so the ground should be solid texture.

    2. Steel girder requirements: the steel beam of the hanging operator shall be no less than 5mm thick, and the bearing capacity shall not be less than 700kg, and shall be treated with rust prevention. Between the steel girder and the finished ground, the error of the drawing shall be no more than plus or minus 3 mm. Acceptance speech on completion of steel girder. Because the top bearing of the automatic door manipulator is 0 kg, the construction and decoration structure above the door body should be finished before the installation of the door body.

    3. Power supply requirements: use safety and inspection interests, and set up independent automatic door power supply (ac 220V, 50HZ, 6A). Power supply cable, a single set of 3 '1.5 mm2 copper sheath cable, one way to protect the earth wire cable should be hidden to automatic door beams above the inside right, and had a certain connection allowance (to central beam).

    Iv. Other requirements:

    1. The automatic door can be connected with the fire alarm system of the building, and when the fire alarm occurs, it is in the evacuation position automatically. The fire alarm signal is a non-source normally open contact signal. Two signal lines are required to be connected with the power supply cable to the automatic door.

    2. The door body parts shall be stored in a place close to the installation site after the arrival of the goods, so as to avoid the damage caused by secondary transport. The storage location shall be safe, rain proof and dustproof.

    3. After the goods are opened, the valuable items of the department should be stored in a room close to the site and locked.

    4. The automatic doors should be checked and accepted in time.

    5. The sensor should be installed outside, usually in the center of the doorway, and the height is determined according to the situation. Please refer to the instruction manual.

    6, prior to installation of electric components guide rail is clean, then the motor, electric plate, tail wheel, transformer, respectively in a fixed orbit groove, move it to the appropriate location, installation of positioning screw.

    Five, the test

    Adjusting controller can be adjusted according to need, but must pay attention to the machine is very sensitive, press gently (specific adjustment in accordance with the electrical plate) if the test everything is normal, sealing cover on the case, mount the sensor're done.

    1. After the automatic door is put into use, there will be a phase of grinding in the initial stage to correct the errors caused by the operation.

    2, very few clients in automatic door operation after a period of time, will replace the door leaf to give people the feeling that find everything new and fresh, must pay attention to is: to strictly limit the weight of the door leaf, no more than rated load of the automatic door machine.

    3. The automatic doors that do not install the safe light must stop the personnel from stopping in the non-inductive range so as to avoid the occurrence of the clipping.

    4. The life of automatic door electrical components is mainly related to improper use and accidental accident; Automatic door under the condition of normal use is parts, guide rail, drive belt and pulley, the dynamic wear of the roller is not only refers to the pulley on the guide rail do uniform motion under the condition of wear and tear, more important is refers to the automatic sliding door wear in the short distance between accelerated motion.

    5. Generally, the automatic door should be cleaned and adjusted in a maximum of one year in three months.


 

all rights reserved ?2015Shanghai Forest Special Steel Door Co., Ltd.
滬ICP備11048493號(hào)